From: Florian Fainelli <f.fainelli@gmail.com>
Date: Tue, 22 May 2018 16:22:26 -0700
Subject: net: phy: broadcom: Fix auxiliary control register reads
Git-commit: 733a969a7ed14fc5786bcc59c1bdda83c7ddb46e
Patch-mainline: v4.17-rc7
References: networking-stable-18_06_08
We are currently doing auxiliary control register reads with the shadow
register value 0b111 (0x7) which incidentally is also the selector value
that should be present in bits [2:0]. Fix this by using the appropriate
selector mask which is defined (MII_BCM54XX_AUXCTL_SHDWSEL_MASK).
This does not have a functional impact yet because we always access the
MII_BCM54XX_AUXCTL_SHDWSEL_MISC (0x7) register in the current code.
This might change at some point though.
Fixes: 5b4e29005123 ("net: phy: broadcom: add bcm54xx_auxctl_read")
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Jiri Slaby <jslaby@suse.cz>
---
drivers/net/phy/bcm-phy-lib.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
--- a/drivers/net/phy/bcm-phy-lib.c
+++ b/drivers/net/phy/bcm-phy-lib.c
@@ -56,7 +56,7 @@ int bcm54xx_auxctl_read(struct phy_devic
/* The register must be written to both the Shadow Register Select and
* the Shadow Read Register Selector
*/
- phy_write(phydev, MII_BCM54XX_AUX_CTL, regnum |
+ phy_write(phydev, MII_BCM54XX_AUX_CTL, MII_BCM54XX_AUXCTL_SHDWSEL_MASK |
regnum << MII_BCM54XX_AUXCTL_SHDWSEL_READ_SHIFT);
return phy_read(phydev, MII_BCM54XX_AUX_CTL);
}