From a8d6d4992ad9d92356619ac372906bd29687bb46 Mon Sep 17 00:00:00 2001
From: Arseny Demidov <arsdemal@gmail.com>
Date: Sun, 19 Dec 2021 13:22:39 +0300
Subject: [PATCH] hwmon: (mr75203) fix wrong power-up delay value
Git-commit: a8d6d4992ad9d92356619ac372906bd29687bb46
Patch-mainline: v5.17-rc1
References: git-fixes
In the file mr75203.c we have a macro named POWER_DELAY_CYCLE_256,
the correct value should be 0x100. The register ip_tmr is expressed
in units of IP clk cycles, in accordance with the datasheet.
Typical power-up delays for Temperature Sensor are 256 cycles i.e. 0x100.
Fixes: 9d823351a337 ("hwmon: Add hardware monitoring driver for Moortec MR75203 PVT controller")
Signed-off-by: Arseny Demidov <a.demidov@yadro.com>
Link: https://lore.kernel.org/r/20211219102239.1112-1-a.demidov@yadro.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Acked-by: Takashi Iwai <tiwai@suse.de>
---
drivers/hwmon/mr75203.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/hwmon/mr75203.c b/drivers/hwmon/mr75203.c
index 868243dba1ee..1ba1e3145969 100644
--- a/drivers/hwmon/mr75203.c
+++ b/drivers/hwmon/mr75203.c
@@ -93,7 +93,7 @@
#define VM_CH_REQ BIT(21)
#define IP_TMR 0x05
-#define POWER_DELAY_CYCLE_256 0x80
+#define POWER_DELAY_CYCLE_256 0x100
#define POWER_DELAY_CYCLE_64 0x40
#define PVT_POLL_DELAY_US 20
--
2.31.1