Blob Blame History Raw
From: Kevin Barnett <kevin.barnett@microchip.com>
Date: Fri, 8 Jul 2022 13:47:31 -0500
Subject: scsi: smartpqi: Stop logging spurious PQI reset failures
Patch-mainline: v6.0-rc1
Git-commit: 85b41834b0f43b3e5c079ea9ea9288b2568b8c60
References: jsc#PED-1557

Change method used to detect controller firmware crash during PQI reset.

PQI reset can fail with error -6 if firmware takes > 100ms to complete
reset.

Method used by driver to detect controller firmware crash during PQI was
incorrect in some cases.

Link: https://lore.kernel.org/r/165730605108.177165.1132931838384767071.stgit@brunhilda
Reviewed-by: Scott Benesh <scott.benesh@microchip.com>
Reviewed-by: Scott Teel <scott.teel@microchip.com>
Reviewed-by: Mike McGowen <mike.mcgowen@microchip.com>
Signed-off-by: Kevin Barnett <kevin.barnett@microchip.com>
Signed-off-by: Don Brace <don.brace@microchip.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Acked-by: Martin Wilck <mwilck@suse.com>
---
 drivers/scsi/smartpqi/smartpqi_init.c |    3 +--
 1 file changed, 1 insertion(+), 2 deletions(-)

--- a/drivers/scsi/smartpqi/smartpqi_init.c
+++ b/drivers/scsi/smartpqi/smartpqi_init.c
@@ -7412,8 +7412,7 @@ static int pqi_wait_for_pqi_reset_comple
 		reset_reg.all_bits = readl(&pqi_registers->device_reset);
 		if (reset_reg.bits.reset_action == PQI_RESET_ACTION_COMPLETED)
 			break;
-		pqi_check_ctrl_health(ctrl_info);
-		if (pqi_ctrl_offline(ctrl_info)) {
+		if (!sis_is_firmware_running(ctrl_info)) {
 			rc = -ENXIO;
 			break;
 		}