From: Huazhong Tan <tanhuazhong@huawei.com>
Date: Sat, 4 Jan 2020 10:49:31 +0800
Subject: net: hns3: modify an unsuitable reset level for hardware error
Patch-mainline: v5.6-rc1
Git-commit: 7f39febf2e08a227e9696d2ebac2637d9ed98efc
References: bsc#1154353

According to hardware user manual, when hardware reports error
'roc_pkt_without_key_port', the driver should assert function
reset to do the recovery.

So this patch uses HNAE3_FUNC_RESET to replace HNAE3_GLOBAL_RESET.

Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Acked-by: Thomas Bogendoerfer <tbogendoerfer@suse.de>
---
 drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_err.c |    4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

--- a/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_err.c
+++ b/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_err.c
@@ -505,7 +505,7 @@ static const struct hclge_hw_error hclge
 
 static const struct hclge_hw_error hclge_ssu_port_based_err_int[] = {
 	{ .int_msk = BIT(0), .msg = "roc_pkt_without_key_port",
-	  .reset_level = HNAE3_GLOBAL_RESET },
+	  .reset_level = HNAE3_FUNC_RESET },
 	{ .int_msk = BIT(1), .msg = "tpu_pkt_without_key_port",
 	  .reset_level = HNAE3_GLOBAL_RESET },
 	{ .int_msk = BIT(2), .msg = "igu_pkt_without_key_port",
@@ -599,7 +599,7 @@ static const struct hclge_hw_error hclge
 
 static const struct hclge_hw_error hclge_ssu_port_based_pf_int[] = {
 	{ .int_msk = BIT(0), .msg = "roc_pkt_without_key_port",
-	  .reset_level = HNAE3_GLOBAL_RESET },
+	  .reset_level = HNAE3_FUNC_RESET },
 	{ .int_msk = BIT(9), .msg = "low_water_line_err_port",
 	  .reset_level = HNAE3_NONE_RESET },
 	{ .int_msk = BIT(10), .msg = "hi_water_line_err_port",