From: Nicolas Saenz Julienne <nsaenzjulienne@suse.de>
Date: Tue, 18 Feb 2020 12:14:25 +0100
Subject: soc: bcm2835: Sync xHCI reset firmware property with downstream
Patch-mainline: Submitted, https://lkml.org/lkml/2020/3/6/317
References: bsc#1163560
The property is needed in order to trigger VL805's firmware load. Note
that there is a gap between the property introduced and the previous
one. This is also the case downstream.
Signed-off-by: Nicolas Saenz Julienne <nsaenzjulienne@suse.de>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
---
include/soc/bcm2835/raspberrypi-firmware.h | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/include/soc/bcm2835/raspberrypi-firmware.h b/include/soc/bcm2835/raspberrypi-firmware.h
index 7800e12ee042..cc9cdbc66403 100644
--- a/include/soc/bcm2835/raspberrypi-firmware.h
+++ b/include/soc/bcm2835/raspberrypi-firmware.h
@@ -90,7 +90,7 @@ enum rpi_firmware_property_tag {
RPI_FIRMWARE_SET_PERIPH_REG = 0x00038045,
RPI_FIRMWARE_GET_POE_HAT_VAL = 0x00030049,
RPI_FIRMWARE_SET_POE_HAT_VAL = 0x00030050,
-
+ RPI_FIRMWARE_NOTIFY_XHCI_RESET = 0x00030058,
/* Dispmanx TAGS */
RPI_FIRMWARE_FRAMEBUFFER_ALLOCATE = 0x00040001,