From: James Smart <jsmart2021@gmail.com>
Date: Tue, 30 Jan 2018 15:58:50 -0800
Subject: scsi: lpfc: Fix PRLI handling when topology type changes
Patch-mainline: v4.17-rc1
Git-commit: 2c3b2a8f652566c5b35d945f0c8146555d2062ec
References: bsc#1080657
The lpfc driver does not discover a target when the topology changes
from switched-fabric to direct-connect. The target rejects the PRLI from
the initiator in direct-connect as the driver is using the old S_ID from
the switched topology.
The driver was inappropriately clearing the VP bit to register the VPI,
which is what is associated with the S_ID.
Fix by leaving the VP bit set (it was set earlier) and as the VFI is
being re-registered, set the UPDT bit.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Acked-by: Johannes Thumshirn <jthumshirn@suse.de>
---
drivers/scsi/lpfc/lpfc_mbox.c | 4 +---
1 file changed, 1 insertion(+), 3 deletions(-)
--- a/drivers/scsi/lpfc/lpfc_mbox.c
+++ b/drivers/scsi/lpfc/lpfc_mbox.c
@@ -2170,10 +2170,8 @@ lpfc_reg_vfi(struct lpfcMboxq *mbox, str
/* Only FC supports upd bit */
if ((phba->sli4_hba.lnk_info.lnk_tp == LPFC_LNK_TYPE_FC) &&
(vport->fc_flag & FC_VFI_REGISTERED) &&
- (!phba->fc_topology_changed)) {
- bf_set(lpfc_reg_vfi_vp, reg_vfi, 0);
+ (!phba->fc_topology_changed))
bf_set(lpfc_reg_vfi_upd, reg_vfi, 1);
- }
bf_set(lpfc_reg_vfi_bbcr, reg_vfi, 0);
bf_set(lpfc_reg_vfi_bbscn, reg_vfi, 0);