Blob Blame History Raw
From 9452fbf5c6cf5f470e0748fe7a14a683e7765f7a Mon Sep 17 00:00:00 2001
From: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
Date: Tue, 18 Jun 2019 15:31:02 +0200
Subject: [PATCH] platform/x86: pmc_atom: Add CB4063 Beckhoff Automation board to critclk_systems DMI table
Git-commit: 9452fbf5c6cf5f470e0748fe7a14a683e7765f7a
Patch-mainline: v5.3-rc1
References: bsc#1051510

The CB4063 board uses pmc_plt_clk* clocks for ethernet controllers. This
adds it to the critclk_systems DMI table so the clocks are marked as
CLK_CRITICAL and not turned off.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Acked-by: Takashi Iwai <tiwai@suse.de>

---
 drivers/platform/x86/pmc_atom.c | 8 ++++++++
 1 file changed, 8 insertions(+)

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index 2104e1ad38d9..005634c11ebe 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -400,6 +400,14 @@ static const struct dmi_system_id critclk_systems[] = {
 			DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
 		},
 	},
+	{
+		/* pmc_plt_clk* - are used for ethernet controllers */
+		.ident = "Beckhoff CB4063",
+		.matches = {
+			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
+			DMI_MATCH(DMI_BOARD_NAME, "CB4063"),
+		},
+	},
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff CB6263",
-- 
2.16.4