From ce277959d77c4cb8b794afab342c3ac24159dc9d Mon Sep 17 00:00:00 2001
From: Frieder Schrempf <frieder.schrempf@kontron.de>
Date: Fri, 15 Oct 2021 14:48:36 +0200
Subject: [PATCH] arm64: dts: imx8mm-kontron: Make sure SOC and DRAM supply voltages are correct
Git-commit: 82a4f329b133ad0de66bee12c0be5c67bb8aa188
Patch-mainline: v5.15
References: stable-5.14.16
commit 82a4f329b133ad0de66bee12c0be5c67bb8aa188 upstream.
It looks like the voltages for the SOC and DRAM supply weren't properly
validated before. The datasheet and uboot-imx code tells us that VDD_SOC
should be 800 mV in suspend and 850 mV in run mode. VDD_DRAM should be
950 mV for DDR clock frequencies of up to 1.5 GHz.
Let's fix these values to make sure the voltages are within the required
range.
Fixes: 8668d8b2e67f ("arm64: dts: Add the Kontron i.MX8M Mini SoMs and baseboards")
Cc: stable@vger.kernel.org
Signed-off-by: Frieder Schrempf <frieder.schrempf@kontron.de>
Signed-off-by: Shawn Guo <shawnguo@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Acked-by: Takashi Iwai <tiwai@suse.de>
---
arch/arm64/boot/dts/freescale/imx8mm-kontron-n801x-som.dtsi | 6 ++++--
1 file changed, 4 insertions(+), 2 deletions(-)
diff --git a/arch/arm64/boot/dts/freescale/imx8mm-kontron-n801x-som.dtsi b/arch/arm64/boot/dts/freescale/imx8mm-kontron-n801x-som.dtsi
index bd8b0ced26ef..42bbbb3f532b 100644
--- a/arch/arm64/boot/dts/freescale/imx8mm-kontron-n801x-som.dtsi
+++ b/arch/arm64/boot/dts/freescale/imx8mm-kontron-n801x-som.dtsi
@@ -91,10 +91,12 @@ regulators {
reg_vdd_soc: BUCK1 {
regulator-name = "buck1";
regulator-min-microvolt = <800000>;
- regulator-max-microvolt = <900000>;
+ regulator-max-microvolt = <850000>;
regulator-boot-on;
regulator-always-on;
regulator-ramp-delay = <3125>;
+ nxp,dvs-run-voltage = <850000>;
+ nxp,dvs-standby-voltage = <800000>;
};
reg_vdd_arm: BUCK2 {
@@ -111,7 +113,7 @@ reg_vdd_arm: BUCK2 {
reg_vdd_dram: BUCK3 {
regulator-name = "buck3";
regulator-min-microvolt = <850000>;
- regulator-max-microvolt = <900000>;
+ regulator-max-microvolt = <950000>;
regulator-boot-on;
regulator-always-on;
};
--
2.26.2