From: Chris Lesiak <chris.lesiak@licor.com>
Date: Thu, 21 Nov 2019 20:39:42 +0000
Subject: iio: humidity: hdc100x: fix IIO_HUMIDITYRELATIVE channel reporting
Git-commit: 342a6928bd5017edbdae376042d8ad6af3d3b943
Patch-mainline: 5.5-rc2
References: bnc#1151927 5.3.17
The IIO_HUMIDITYRELATIVE channel was being incorrectly reported back
as percent when it should have been milli percent. This is via an
incorrect scale value being returned to userspace.
Signed-off-by: Chris Lesiak <chris.lesiak@licor.com>
Acked-by: Matt Ranostay <matt.ranostay@konsulko.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Jiri Slaby <jslaby@suse.cz>
---
drivers/iio/humidity/hdc100x.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
--- a/drivers/iio/humidity/hdc100x.c
+++ b/drivers/iio/humidity/hdc100x.c
@@ -229,7 +229,7 @@ static int hdc100x_read_raw(struct iio_d
*val2 = 65536;
return IIO_VAL_FRACTIONAL;
} else {
- *val = 100;
+ *val = 100000;
*val2 = 65536;
return IIO_VAL_FRACTIONAL;
}